Tel : 0514-88223630 88221954 88238287
Fax: 0514-88232382 88223630
Address:Baoying County in Jiangsu Province on the 11th Mountain Road
Website: http://www.kelongmotor.com
 Motor >>  Z710-type DC motor >> Details
 
  
    Product Description
Model Z710 DC
Model Z710 DC motor is our newly developed Z series DC motor, the center height of 770 mm. Due to the structure and properties of Z710 type motor is unique, there is some difference between the medium and Z series DC motor.
 
Two, the use of conditions
1 motor can be mounted on the environmental condition is bad situations, but must choose proper cooling and protection level, to keep the machine clean inside.
2 Should not contain acid, alkali, the insulation of the motor and reversing property damage to the electricity gas cooling air.
3 motor such as the use of the ship and the wet tropics and working environment with salt spray, humidity, should be a separate agreement.
4 Rated power motor is at an altitude of less than 1000 meters, the ambient air temperature is not more than 40C under the conditions of.
5 The power supply of  motor using static rectifier power supply, also can use DC generator.
 
Three, the product structure
The motor frame by polygonal laminations, has the advantages of small volume, light weight, suitable for silicon controlled rectifier power supply. The motor insulation class F. Solventless varnish vacuum pressure impregnation treatment using motor ( VP ", make the winding insulation has good moisture resistance capability, mechanical strength and excellent thermal conductivity. Armature core made of silicon steel sheets which are stacked together, with good magnetic properties of motors with rolling bearings, stable operation. Mounting the motor in accordance with GB997 and IEC34-7 " motor structure and installation form code "
Standard IM1001 end cover bearing, foot mounting, horizontal, cylindrical uniaxial extension
Can be derived with IM1002 cover type bearing, foot mounting, horizontal, cylindrical shaft
Motor protection grade according to GB4942.1 and IEC34-5 " motor shell protection grade " standard, shell protection grade standard motor has IP22 and IP44 two. Motor cooling methods according to GB1993 and IEC34 - 6 " motor cooling method " standard. The standard motor has ICl7, IC37 and ICW37A86 three. If you need other protection grade, the cooling method can be negotiated. The standard type of cooling air entrance in the motor drive end ( non commutator end ).
 
Four, product performance
1, the motor of the quota for continuous conduction mode ( SI ).
2 ,Standard of rated voltage the motor of 440V, 660V, 750V three.
3,Excitation mode the motor is excited, exciting windings have four lead terminals, divided into two groups of two series excitation voltage is 220V, the parallel excitation voltage is 110V. The actual excitation voltage motor, should be based on the actual motor excitation current reaches the rated value as the standard, the motor allow forced excitation, forcing voltage shall not exceed 500V. Strong excitation, excitation current can be instantaneous slightly more than the rated excitation current, but the excitation current is stable, not more than.
4, overload capacity of the motor:
The first kind of DC motor ( Class A ) can withstand short time required under the table ( one minute) overload.
 

The base of the percentage
The percentage of rated current
For occasional use
Often use
100
200
175
200
160
150
300以上
140
125

 
Second types of DC motor ( B ) can withstand short time required under the table ( one minute) overload.
 

The base of the percentage
The percentage of rated current
For occasional use
Often use
100
200
175
200
200
160
300以上
175
140

 
Second types of DC motors ( class B ) shall bear the following continuous load:
( 1 ) with 115% rated load for continuous operation at rated armature voltage and rated speed range, the load, temperature will be higher, other properties may be specified and rated to run under the conditions of different.
( 2 ) rated armature voltage and rated speed range, continuous operation at rated load, followed by 125% of rated power for two hours, the temperature does not exceed the prescribed value, other properties may be specified and the rated operating under different values of.
* short-term overload capacity for occasional use is rarely occurred or in the case of an emergency, the motor bearing capacity of more than continuous rated load in a minute, suggest the instantaneous circuit breaker device according to the short-time overload the occasional use of setting. Short-time overload ability.
 * * use often refers as part of normal work of the motor cycle, to bear the beyond the rated load.
* * * After the short-time overload operation, must be running with light load, so the load motor cycle load RMS value does not exceed its continuous rating. On second types of DC motors ( B ), occasionally use overload allows up to 2.5 times ( at rated base speed ), no more than 15 seconds ( but in consultation with the company ).
5, the current rate of change
In all the speed and load current changes, motor rate ( di / DT ) allows up to 200 times the rated current / S.
6, the noise and vibration
The motor " noise measurement methods and limits " in line with the national standard GBl0069.3.
" The motor vibration measurement method and limits " in line with the national standard GBl0068.2.
 
Five, capacity selection
The first kind of DC motor ( class A ):
Detailed data on this kind of motor see technical data sheet, the user can according to the required capacity, speed and voltage selected motor model and the specification.
Second types of DC motor ( B ):
Power, current technology of data of this kind of motor than a technical data sheet of the value is low, but the actual value to be set by the user and manufacturing company.
In addition to the motor specifications listed technical data, the user can according to the specific needs and manufacturing company consultations, derived from other specifications of DC motor.
 
 
Six technicial date(class A)
 
Z710-320 is suitable for cooling  Applied to the cooling types of IC17,IC37,ICW37A86
Number
Rated voltage speed
Power
Rated
Current
Efficiency
The maximum
speed
Excition power
Rotation
Inertia
Ventilate
440V
660V
750V
Air quantity
wind presssure
1
480
 
 
800
1963
92.6
1100
8.5
289
4.0
0.85
2
560
 
 
1000
2473
93.3
1100
10
296
4.6
1.08
3
 
530
 
1000
1621
93.4
1100
10
289
4.4
1.0
4
 
745
 
1250
2021
93.7
1200
8.4
289
5.1
1.3
5
 
 
645
1250
1775
93.9
1100
9.8
296
5.0
1.26
6
 
860
 
1500
2423
93.8
1100
8.7
296
6.0
1.75
7
 
 
845
1500
2129
93.9
1200
8.2
289
5.9
1.7
 
Z710-400 is suitable for cooling
 
 Applied to the cooling types of IC17,IC37,ICW37A86
Number
Rated voltage speed
Power
Rated
Current
Efficiency
The maximum
speed
Excition power
Air quantity
Rotation
Inertia
Ventilate
440V
660V
750V
Air quantity
wind presssure
1
380
 
 
800
1967
92.4
1000
9.3
337
4.2
0.93
2
445
 
 
1000
2440
93.2
1000
10.9
344
4.7
1.13
3
 
422
 
1000
1624
93.3
1000
10.6
337
4.6
1.08
4
 
590
 
1250
2019
93.8
1100
8.7
337
5.1
1.3
5
 
 
515
1250
1774
93.9
1000
10.5
344
5.1
1.3
6
 
690
 
1500
2418
94
1000
9.13
344
5.9
1.7
7
 
 
680
1500
2125
94.1
1100
8.5
337
5.7
1.6
 
 
 
 
 
Z710-500 is suitable for cooling      Applied to the cooling types of IC17,IC37,ICW37A86
Number
Rated voltage speed
Power
Rated
Current
Efficiency
The maximum
speed
Excition power
Air quantity
Rotation
Inertia
Ventilate
440V
660V
750V
Air quantity
wind presssure
1
305
 
 
800
1975
92.1
800
10.4
397
4.4
1.0
2
360
 
 
1000
2446
92.9
800
11
404
4.8
1.17
3
 
337
 
1000
1625
93.2
800
11.6
397
4.7
1.13
4
 
470
 
1250
2021
93.7
1000
10.1
397
5.2
1.35
5
 
 
410
1250
1777
93.8
800
11.4
404
5.2
1.35
6
 
550
 
1500
2419
94
800
10.6
404
6.0
1.75
7
 
 
530
1500
2125
94.1
1000
10.9
397
5.8
1.65
 
 
 
 
 
Z710-630 is suitable for cooling  
 
Applied to the cooling types of IC17,IC37,ICW37A86
 
Number
Rated voltage speed
Power
Rated
Current
Efficiency
The maximum
speed
Excition power
Air quantity
Rotation
Inertia
Ventilate
440V
660V
750V
Air quantity
wind presssure
1
240
 
 
800
1988
91.4
700
11.9
475
4.8
1.17
2
280
 
 
1000
2458
92.5
700
13.3
482
5.3
1.4
3
 
268
 
1000
1633
92.8
700
12.7
475
5.0
1.26
4
 
370
 
1250
2027
93.4
800
11.8
475
5.5
1.49
5
 
 
325
1250
1783
93.5
700
12.7
482
5.5
1.49
6
 
435
 
1500
2425
93.7
700
12.1
482
6.3
1.92
7
 
 
430
1500
2129
93.9
800
11.1
475
6.0
1.75
 
 
 
 
Z710-800 is suitable for cooling  
 
Applied to the cooling types of IC17,IC37,ICW37A86
 
Number
Rated voltage speed
Power
Rated
Current
Efficiency
The maximum
speed
Excition power
Air quantity
Rotation
Inertia
Ventilate
440V
660V
750V
Air quantity
wind presssure
1
185
 
 
800
2008
90.5
550
14.5
576
5.5
1.49
2
220
 
 
1000
2477
91.7
550
14.2
583
5.8
1.65
3
 
210
 
1000
1645
92.1
550
13.7
576
5.5
1.49
4
 
290
 
1250
2038
93
700
13.6
576
6.1
1.81
5
 
 
255
1250
1793
92.9
550
13.8
583
6.0
1.75
6
 
345
 
1500
2436
93.3
550
13.4
583
6.8
2.21
7
 
 
325
1500
2138
93.3
700
13.6
576
6.5
2.03
 
 
 
 
 
 
 
 
 
Seven, outline and mounting dimension table
Pipe ventilation ( IC17 )
The half pipe ventilation ( IC37 )
Mode
Foot size
Shaft extension
Size
The outlet box  Size
H   L   C   HD
A
B
K
HA
AB
BB
AA
BA
BA'
D
E
AD
Z710-320
710 1890 355 1415
1400
1120
56
40
1540
1610
200
475
535
250
410
1028
Z710-400
710 1970 355 1415
1400
1250
56
40
1540
1690
200
475
535
250
410
1028
Z710-500
710 2070 355 1415
1400
1250
56
40
1540
1790
200
475
535
250
410
1028
Z710-630
710 2250 355 1415
1400
1400
56
40
1540
1920
200
475
535
250
410
1028
Z710-80
710 2420 355 1415
1400
1600
56
40
1540
2090
200
475
535
250
410
1028
 
With a backpack, air cooler(ICW37A86)
 
Mode
Foot size
Shaft extension
Size
The outlet box  Size
Cooler dimension
L
C
HD
A
B
K
HA
AB
BB
AA
BA
BA'
D
E
AD
LA
AE
HV
Z710-320
710
1890
355
1415
1400
1120
56
40
1540
1610
200
475
535
250
410
1028
2390
1830
3044
Z710-400
710
1970
355
1415
1400
1250
56
40
1540
1690
200
475
535
250
410
1028
2470
1830
3044
Z710-500
710
2070
355
1415
1400
1250
56
40
1540
1790
200
475
535
250
410
1028
2500
1830
3044
Z710-630
710
2250
355
1415
1400
1400
56
40
1540
1920,
200
475
535
250
410
1028
2630
1830
3044
Z710-80, ,
710
2420
355
1415
1400
1600
56
40
1540
2090
200
475
535
250
410
1028
2800
1830
3
 

 

  • On a product: Z2 series DC motor

  • Under a product: Z DC Series Motor
  • Copyright:Jiangsu Kelon Dc Motor Manufacturing Co., Ltd
    Tel:0514-88223630 88228425 88238287 苏ICP备05015556号